SNOW PLOW Energy UNIT

Basic Description
Consisting of a pressure balanced gear pump, DC motor, multi-functional manifold, valves, tank, ect., this energy unit is created to operate material dealing with tools. The reducing movement is achived by the solenoid valve together with the reducing velocity controlled by an adjustable needle valve. The left and correct functions are outfitted having a dual pilot operated check valve and cross-over relief valves.
Remark: Please consult our product sales engineer for your distinct pump displacement, motor power or tank capability.
Specific Notes
one. This energy unit is of S3 duty cycle, i.e.,non-continuous operation,thirty seconds on and 270 seconds off.
two. Clean the many hydraulic components concerned before installation of the electrical power unit.
three. Viscosity of the hydraulic oil shoud be 15~46 cst, which ought to also be clean and free of impurities.N46 hydraulic oil is encouraged.
4. This energy unit really should be mounted horizontal.
5. Check the oil level during the tank right after the primary start off on the electrical power unit.
6. Oil altering is required just after the initial 100 operation hrs, afterwards after every single 3000 hrs.